Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code EF 138: Flame lost during safety time (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code EF 138 on a boiler means: Flame lost during safety time. It is also called Viessmann diagnostic code EF 138.

High severityBoilerVitodens 200-W B2HA

Homeowner? What Viessmann code EF 138 means for you

Call a technician Your boiler is reporting: Flame lost during safety time. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code EF 138 mean?

Burner in fault mode. Flame lost immediately after it has built, during the safety time. Detailed code 138.

Applies to: Vitodens 200-W B2HA 45, 60

Common causes of Viessmann code EF 138

  • Gas supply pressure or gas regulator problem
  • Flue gas recirculation
  • Ionization electrode distance or contamination
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Boiler codes

CodeMeaning
ED 191Internal burner control fault
EEInternal feedback error, gas safety valves
E e0Viessmann 2-wire BUS communication module cable break
EE 132Flame signal missing or weak at burner start
EEEData record error or out-of-range parameter
EFInternal feedback error, gas safety valves
Ext. controlHeating program changed by external control
External Hook-upOperating program changed by external device
FFault shutdown
F.5Sensor circuit fault at plug 33 (X6)
F.7DHW storage tank sensor open circuit
F.8DHW storage tank sensor short circuit

All Viessmann Boiler error codes →

Viessmann code EF 138: homeowner questions

What does Viessmann code EF 138 mean?

Flame lost during safety time. Burner in fault mode. Flame lost immediately after it has built, during the safety time. Detailed code 138.

Is it safe to keep using my boiler with code EF 138?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code EF 138 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code EF 138 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code EF 138 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Vitodens 200-W B2HA 45, 60 Service Instructions, p. 76. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977