Viessmann Boiler: System Layout 3: DHW tank with closely spaced tees

Updated · by Aurora Star Tech Inc.

System Layout 3: DHW tank with closely spaced tees on a Viessmann boiler: Boiler with DHW storage tank and one heating circuit, hydraulically separated by closely spaced tees. A low-loss header is strongly preferred by Viessmann over closely spaced tees.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: B1HE 85, 120, 150, 199 with closely spaced tees

How to fix system layout 3: dhw tank with closely spaced tees: step by step

  1. Space the tees at 4 times the pipe diameter or 12 in (305 mm).
  2. Connect heating circuit pump P2 and the expansion tank.
  3. Run DHW piping at least 1-1/4 in nominal.
  4. Consider a low-loss header instead of tees.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Viessmann Vitodens 100-W B1HE/B1KE Combi Installation and Service Instructions, p. 35. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.