Viessmann Boiler: Burner connection
Burner connection on a Viessmann boiler: The RAST-5 plug goes to the control PCB and the 7-pole plug goes to the burner or wall vent system counter plug. Do not connect the 41-plug from the boiler control directly to the burner when installing a wall vent system.
Applies to: Vitotronic 100 KW10B
How to fix burner connection: step by step
- Connect the RAST-5 plug to the main control circuit board.
- Connect the 7-pole plug to the burner counter plug, or to the wall vent system counter plug if one is installed.
- Do not connect the 41-plug directly to the burner when a wall vent system is used.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Source: Vitotronic 100 KW10B installation manual, p. 13. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.