Viessmann Boiler: Massachusetts side-wall vent CO detector requirements

Updated · by Aurora Star Tech Inc.

Massachusetts side-wall vent CO detector requirements on a Viessmann boiler: For side-wall horizontal venting where the vent end is under 7 ft above grade, a hard-wired CO detector with battery backup must be on the floor level of the installation, and CO detectors with alarms on each additional level. A warning sign must be placed 8 ft above grade in line with the vent.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Installations in the Commonwealth of Massachusetts

How to fix massachusetts side-wall vent co detector requirements: step by step

  1. Confirm hard-wired CO detector with battery backup on the installation floor level.
  2. Confirm CO detectors with alarms on each additional level.
  3. Confirm the 'GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS' sign is installed 8 ft above grade.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

More other tips for boiler

Source: Vitodens 200-W B2HA 45, 60 installation instructions, p. 7. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.