Viessmann Boiler: Boiler short-cycling or inadequate DHW supply
Boiler short-cycling or inadequate DHW supply on a Viessmann boiler: Likely caused by DHW piping that is too small or by a DHW coil whose pressure drop is too high for the boiler pump head.
Applies to: Vitodens 100-W B1HE with DHW storage tank, B1KE
Common causes of boiler short-cycling or inadequate dhw supply
- DHW supply or return piping between boiler and tank is smaller than the minimum stated in the manual.
- Non-Viessmann DHW tank coil pressure drop is higher than the boiler pump head can overcome.
How to fix boiler short-cycling or inadequate dhw supply: step by step
- Check DHW supply and return pipe size against the minimum on page 21 (the size is garbled in this extract; confirm it in the full manual).
- For non-Viessmann tanks, calculate DHW coil pressure drop against boiler pump head.
- Correct piping or tank selection so the boiler heat exchanger gets sufficient flow.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitodens 100-W B1HE/B1KE technical data manual, p. 21 and p. 22. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.