Viessmann Boiler: Rooms cold while burner is operating (single-boiler)
Rooms cold while burner is operating (single-boiler) on a Viessmann boiler: Burner runs but the rooms do not heat properly.
Applies to: Single-boiler systems
Common causes of rooms cold while burner is operating (single-boiler)
- Heating program w or 9 is set (its button is lit)
- DHW priority: boiler is heating the DHW tank first
- Room temperature too low at low outdoor temperature because of incorrect control settings
- Rooms cold during the day but warm at night because of incorrect control settings
How to fix rooms cold while burner is operating (single-boiler): step by step
- If program w or 9 is set, set program rw (see page 6).
- If the DHW tank is being heated, wait until it has reached temperature.
- Check and correct the temperature settings (page 9) and the heating program (page 6).
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitotronic 100, GC1 operating instructions, p. 14. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.