Viessmann Boiler: External changeover of staged/modulating burner
External changeover of staged/modulating burner on a Viessmann boiler: Dry contact at plug aVH selects modulating or two-stage operation.
Applies to: Staged/modulating burners
How to fix external changeover of staged/modulating burner: step by step
- Connect a dry contact to terminals 1 and 2 of plug aVH.
- Contact closed: modulating operation.
- Contact open: two-stage operation. Coding 02: 2 (modulating burner) must be set.
- With the contact closed the burner type scan still shows modulating.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Source: Vitotronic 100, GC1 installation manual, p. 60. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.