Viessmann Boiler: Route and secure field connecting cables
Route and secure field connecting cables on a Viessmann boiler: Keep connecting cables away from hot components, since contact will damage them. Do not exceed the maximum permissible cable temperature. A larger cable (up to 9/16 in.) needs the existing cable grommet removed. Secure the power cable with the grommet seated in the lower orange casing section.
Applies to: Vitodens 200-W B2HB 19, 26, 35, 68, 94, 125
How to fix route and secure field connecting cables: step by step
- Touch a grounded metal object such as a pipe before handling the electronic modules.
- Remove the existing cable grommet if using a larger cable, up to 9/16 in.
- Route all connecting cables to their areas (low voltage, 120 V, communication module, DHW sensor plugs).
- Secure the cables to the control base using the existing strain reliefs.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Vitodens 200-W B2HB 45Vitodens 200-W B2HB 57Vitodens 200-W B2HB 160Vitodens 200-W B2HB 199
More commissioning tips for boiler
Source: Vitodens 200-W B2HB installation manual, p. 24. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.