Updated · by Aurora Star Tech Inc.

Burner mounting on the combustion chamber door on a Viessmann boiler: Mount the burner with the spacer bolts, gasket and nuts supplied. Use the insertion length table on page 41 for the correct air tube depth.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitorond 100 VR1 with oil burner

How to fix burner mounting on the combustion chamber door: step by step

  1. Remove the burner from the carton. The mounting flange is already fitted at the factory.
  2. Install the four M8 spacer bolts in the threaded holes of the combustion chamber door.
  3. Slide the burner gasket over the spacer bolts.
  4. Mount the burner and set the air tube to the insertion length from the page 41 table.
  5. Secure the burner with the M8 nuts and washers supplied.
  6. Follow the burner manufacturer's instructions supplied with the burner.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Vitorond 100 VR1 installation and service manual, p. 27. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.