Viessmann Boiler: Adjusting the barometric draft regulator
Adjusting the barometric draft regulator on a Viessmann boiler: Set the barometric draft regulator so the draft readings are correct, and confirm it moves freely.
Applies to: Vitorond 100 VR1 22 to 33, 91 to 140 with barometric draft regulator
How to fix adjusting the barometric draft regulator: step by step
- Adjust the barometric draft regulator so the over-fire draft is 0.00 to +0.01 in w.c.
- With this setting, the breeching draft should be approximately -0.02 in w.c.
- Confirm the barometric draft regulator moves freely while the burner runs.
If the unit shows an error code, look it up: Viessmann Boiler codes
More commissioning tips for boiler
Source: Vitorond 100, VR1 Installation and Service Instructions, p. 40. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.