Updated · by Aurora Star Tech Inc.

Connect external dry contacts safely on a Viessmann boiler: External contacts on DE1 to DE3 must be floating. Keep the required spacing from live parts.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Digital inputs DE1 to DE3

How to fix connect external dry contacts safely: step by step

  1. Use floating (dry) contacts only.
  2. Keep 8.0 mm air and creep path, or 2.0 mm insulation thickness, from live parts (safety category II).
  3. Only assign one function to each connection.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

More other tips for boiler

Source: Vitodens 200-W B2HA 45, 60 service instructions, p. 83. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.