Viessmann Boiler: Fault lamp on control unit with blinking burner control display
Fault lamp on control unit with blinking burner control display on a Viessmann boiler: Fault after start-up or during gas supply problems. Reset the burner control unit and check the gas supply.
Applies to: CA3B boilers
Common causes of fault lamp on control unit with blinking burner control display
- Insufficient gas in the gas pipe during initial start-up
- Supply side of combination gas valve blocked after gas pipe work
How to fix fault lamp on control unit with blinking burner control display: step by step
- Press reset button R on the burner control unit.
- If the fault continues, check the supply side of the combination gas valve for blockage from gas pipe work.
- On initial start-up, ventilate the gas line again and reset the burner control unit.
- Allow 3 min delay before the burner starts.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
CA3B 2.5 BoilerCA3B 3.0 BoilerCA3B 3.5 BoilerCA3B 4.0 BoilerCA3B 5.0 BoilerCA3B 6.0 BoilerCA3B Series 2.5CA3B Series 3.0CA3B Series 3.5CA3B Series 4.0CA3B Series 5.0CA3B Series 6.0Vitocrossal 300 CA3B 2.5Vitocrossal 300 CA3B 3.5Vitocrossal 300 CA3B 4.0Vitocrossal 300 CA3B 5.0Vitocrossal 300 CA3B 6.0Vitocrossal 300 CA3B Series 2.5Vitocrossal 300 CA3B Series 3.0Vitocrossal 300 CA3B Series 3.5Vitocrossal 300 CA3B Series 4.0Vitocrossal 300 CA3B Series 5.0Vitocrossal 300 CA3B Series 6.0
Source: Vitocrossal 300 CA3B Series 2.5 to 6.0 service instructions, p. 33. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.