Viessmann Boiler: Clean condensate siphon (P-trap)
Clean condensate siphon (P-trap) on a Viessmann boiler: Keep the condensate siphon clear so condensate drains freely.
Applies to: Vitodens 100-W, WB1B
Common causes of clean condensate siphon (p-trap)
- Blocked siphon
- Condensate not draining freely
How to fix clean condensate siphon (p-trap): step by step
- Check the siphon for unimpeded drainage.
- Remove all hoses from the siphon.
- Release the locking tabs underneath and lift the siphon out.
- Clean the siphon and reinstall it.
- Refit all hoses and secure the drain hose with cable ties.
- Fill the siphon by pouring 0.3 L (10 fl. oz.) of water into the combustion chamber.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Viessmann Vitodens 100-W, WB1B installation and service instructions, p. 69. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.