Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Boiler: Reset faults with the tr rotary selector

Updated · by Aurora Star Tech Inc.

Reset faults with the tr rotary selector on a Viessmann boiler: Turning the tr selector to the reset position clears a fault. If no fault is present, the boiler goes into relay test mode instead. Turn the boiler off and back on to exit.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 100-W WB1B

How to fix reset faults with the tr rotary selector: step by step

  1. Turn the tr rotary selector to "U Reset".
  2. Pause until "SERV" appears on the screen.
  3. Within 2 seconds, turn tr back into the control range.
  4. To leave relay test mode, turn the boiler off and back on.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

WB1AWB1B

More reset & cancel tips for boiler

Source: Vitodens 100-W WB1B installation and service instructions, p. 76. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.