Viessmann Boiler: Reset faults with the tr rotary selector
Reset faults with the tr rotary selector on a Viessmann boiler: Turning the tr selector to the reset position clears a fault. If no fault is present, the boiler goes into relay test mode instead. Turn the boiler off and back on to exit.
Applies to: Vitodens 100-W WB1B
How to fix reset faults with the tr rotary selector: step by step
- Turn the tr rotary selector to "U Reset".
- Pause until "SERV" appears on the screen.
- Within 2 seconds, turn tr back into the control range.
- To leave relay test mode, turn the boiler off and back on.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
More reset & cancel tips for boiler
Source: Vitodens 100-W WB1B installation and service instructions, p. 76. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.