Viessmann Boiler: Carbon monoxide detector requirement (Massachusetts)
Carbon monoxide detector requirement (Massachusetts) on a Viessmann boiler: For side-wall horizontally vented gas equipment with the vent termination under 7 ft above grade, Massachusetts rules require CO detectors with alarm and battery backup on the floor where the appliance is installed, plus detectors on each additional level. A metal or plastic sign reading GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS must be mounted at least 8 ft above grade in line with the vent terminal. If the detector cannot be installed at completion, a battery detector is required for 30 days.
Applies to: Installations in the Commonwealth of Massachusetts
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Viessmann Vitodens 200-W B2HA service instructions, p. 8. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.