Viessmann Boiler: Allocating heating circuits to a remote control

Updated · by Aurora Star Tech Inc.

Allocating heating circuits to a remote control on a Viessmann boiler: Vitotrol 200A and Vitotrol 300A must be assigned to a heating circuit when commissioning. One heating circuit can be assigned to the Vitotrol 200A. Up to three can be assigned to the Vitotrol 300A. Up to two remote controls can be connected.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitotrol 200A and Vitotrol 300A remote controls

How to fix allocating heating circuits to a remote control: step by step

  1. Assign the heating circuit during commissioning of the Vitotrol 200A or 300A.
  2. If the assignment is later cancelled, reset coding address A0 for that heating circuit to 0.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

B2HB 45B2HB 45, 160B2HB 57B2HB 57, 199B2HB 160B2HB 199

Source: Vitodens 200-W B2HA service instructions, p. 94. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.