Route boiler flue (venting) through wall or roof on a Viessmann boiler: Single-wall or coaxial venting can exit through the side wall or the roof. The boiler ships with a pre-installed vent adaptor.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 200-W B2HB venting

How to fix route boiler flue (venting) through wall or roof: step by step

  1. Run the venting system (single-wall or coaxial) by the shortest practical route.
  2. Keep a rising slope of at least 3 degrees toward the outlet.
  3. Support the piping so it does not rest on or load the boiler. Use only a moderate amount of pipe dope.
  4. For single-wall venting in a room-air-dependent installation, remove the outer gasket.
  5. If using the combustion air inlet seal, remove the seal, tear out the centre section and refit the remaining rubber seal into the air inlet opening.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

B2HB 45B2HB 45, 160B2HB 57B2HB 57, 199B2HB 160B2HB 199

Source: Vitodens 200-W B2HB installation manual, p. 18. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.