aBJ programmable output function on a Viessmann boiler: The aBJ output is a programmable function output. It can be coded for only one function: alarm output, DHW recirculation pump, field pump or zone circuit pump. Maximum output is 2 FLA.
Applies to: Vitocrossal 300 CU3A 26 to 199, extension module EA1
How to fix abj programmable output function: step by step
- Select one function for the aBJ output using the coding in the Service Instructions.
- Keep the load within 2 FLA.
- See the wiring diagram on page 57 for connection to the control base.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
CU3I 2ZC2ZP.01CU3I 3HC/Z3ZP.01CU3X 1ZC1ZP.01Vitocrossal 300 CU3A 26Vitocrossal 300 CU3A 35Vitocrossal 300 CU3A 45Vitocrossal 300 CU3A 57Vitocrossal 300 CU3A 94Vitocrossal 300 CU3A 125Vitocrossal 300 CU3A 160Vitocrossal 300 CU3A 199
Source: Vitocrossal 300 CU3A 26 to 199 Installation Instructions, p. 37. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.