Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Boiler: Mount oil burner on combustion chamber door

Updated · by Aurora Star Tech Inc.

Mount oil burner on combustion chamber door on a Viessmann boiler: Mount the flange and burner per the burner instructions. For Riello tube insert adjustment, see the calibration chart on p. 38.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Oil burner mounting

How to fix mount oil burner on combustion chamber door: step by step

  1. Remove the burner from the carton. The mounting flange is factory installed.
  2. Mount four M8 spacer bolts in the threaded holes of the combustion chamber door.
  3. Slide the burner gasket over the spacer bolts.
  4. Mount the burner as shown.
  5. Secure the burner with the M8 nuts and washers provided.
  6. Set the burner air tube insertion per the burner manufacturer's instructions.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Vitorond 100 VR1 installation and service manual, p. 24. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair