Viessmann Boiler: Checking the DHW, low loss header, heating circuit or room temperature sensor
Checking the DHW, low loss header, heating circuit or room temperature sensor on a Viessmann boiler: Resistance check of these sensors against the curve in the manual.
Applies to: Vitocrossal 300 CU3A 26 to 199
Common causes of checking the dhw, low loss header, heating circuit or room temperature sensor
- Faulty sensor
- Faulty sensor lead
How to fix checking the dhw, low loss header, heating circuit or room temperature sensor: step by step
- Pull the leads from the temperature sensor.
- Measure the sensor resistance and compare it with the curve.
- Replace the sensor if the deviation is severe.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
CU3I 2ZC2ZP.01CU3I 3HC/Z3ZP.01CU3X 1ZC1ZP.01Vitocrossal 300 CU3A 26Vitocrossal 300 CU3A 35Vitocrossal 300 CU3A 45Vitocrossal 300 CU3A 57Vitocrossal 300 CU3A 94Vitocrossal 300 CU3A 125Vitocrossal 300 CU3A 160Vitocrossal 300 CU3A 199
Source: Vitocrossal 300 CU3A 26 to 199 Service Instructions, p. 94. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.