Viessmann Boiler: Enter coding level 1 and change a code
Enter coding level 1 and change a code on a Viessmann boiler: Opens the coding menu to change boiler, system and heating circuit codes.
Applies to: Vitotronic 200-H, Vitodens 200-W B2HB
How to fix enter coding level 1 and change a code: step by step
- Press OK and the second menu button together for about 4 seconds (button symbol not legible in this copy).
- Select Coding level 1.
- Select the group needed: General, Boiler, DHW, Solar, Heating circuit 1/2/3, or All codes std device.
- Select the coding address.
- Select the value from the tables and confirm with OK.
- To reset all codes to factory settings, select Standard setting in Coding level 1. This also resets coding level 2 codes.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Vitodens 200-W B2HB 45Vitodens 200-W B2HB 57Vitodens 200-W B2HB 160Vitodens 200-W B2HB 199
More access & passwords tips for boiler
Source: Vitodens 200-W B2HB service instructions, p. 42. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.