Viessmann Boiler: Heating programs and what they do
Heating programs and what they do on a Viessmann boiler: The heating program decides whether the system heats rooms and DHW, DHW only, or stays in standby with frost protection. Winter mode is 'Heating and DHW'. Summer mode is 'Only DHW', where the boiler still makes DHW but no central heating. 'Standby mode' turns off central heating and DHW but keeps frost protection active for the boiler and DHW tank. There is no heating-only program. For heating without DHW demand, select 'Heating and DHW' and set the DHW temperature to 10 °C (50 °F). DHW is then not heated needlessly, and the DHW tank stays frost protected.
Applies to: Vitotronic 200 and 300-K heating program
How to fix heating programs and what they do: step by step
- Select 'Heating and DHW' for winter operation with rooms and DHW.
- Select 'Only DHW' for summer operation.
- Select 'Standby mode' to shut down heating and DHW while keeping frost protection.
- For central heating only, select 'Heating and DHW' and set the DHW temperature to 10 °C (50 °F).
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Vitotronic 200
HO1BKW2Vitotronic 200, type H01BVitotronic 200, Type HO1B
Vitotronic 300-K
MW1SVitotronic 300-K, type MW2B
Source: Vitotronic 200 and 300-K Operating Instructions, p. 43. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.