Viessmann Boiler: Set the holiday energy saving program
Set the holiday energy saving program on a Viessmann boiler: Reduces energy use while away. With the 'rw' heating program, space heating runs at the reduced room temperature but DHW is off. With the 'w' program, only frost protection runs. DHW follows its time program on departure and return dates.
Applies to: Vitotronic 200-H holiday program
How to fix set the holiday energy saving program: step by step
- Open the cover on the programming unit.
- Press j; the 'Holiday program' display appears.
- Press confirm, then use the up/down buttons to set the departure date and confirm.
- Use the up/down buttons to set the return date and confirm.
- If in the 'rw' program, press tm to set the holiday temperature, adjust with the up/down buttons and confirm.
- Close the hinged cover.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
HK1BHK1MHK1SHK3SVitotrol 200Vitotrol 300
Source: Vitotronic 200-H operating instructions, p. 20-21. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.