Viessmann Boiler: Underfloor plastic tubing without oxygen barrier
Underfloor plastic tubing without oxygen barrier on a Viessmann boiler: Underfloor plastic tubing without an oxygen diffusion barrier can cause corrosion. Such a system must be separated from the boiler with a heat exchanger. The warranty does not cover resulting leaks.
Applies to: Vitorond 200 VD2A hydronic system
How to fix underfloor plastic tubing without oxygen barrier: step by step
- Separate non-barrier underfloor tubing from the boiler with a heat exchanger.
- Use underfloor tubing with an oxygen diffusion barrier where possible.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitorond 200 VD2A technical data manual, p. 25. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.