Viessmann Boiler: Coco OT single boiler DIP setting and connection
Coco OT single boiler DIP setting and connection on a Viessmann boiler: Single boiler installations use one Coco OT with DIP switch setting for a single boiler. The Coco OT is wired to the CAN connections, and DHW can be handled on the CAN side.
Applies to: Single modulating boiler with Coco OT
How to fix coco ot single boiler dip setting and connection: step by step
- Wire H and L to the CAN BUS terminals, observing polarity.
- Wire + and - to the CAN power supply terminals.
- Set the DIP switches to the single boiler setting (see the DIP switch setting table).
- Plug in the 4-pole connector after the interconnections are done.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Versatronik 200 installation and operating manual, p. 18. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.