Updated · by Aurora Star Tech Inc.

Sensor wiring near high voltage on a Viessmann boiler: Long sensor runs can pick up electromagnetic interference. Keep sensor wiring away from 120/240 VAC conductors. If that is not possible, use stranded, twisted pair or shielded wire and ground only one end of the shield.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: All Vitotronic 300 GW2 sensor and extension wiring

How to fix sensor wiring near high voltage: step by step

  1. Route sensor wire away from 120/240 VAC conductors.
  2. If a crossing cannot be avoided, use stranded, twisted pair or shielded wire.
  3. Ground only one end of the shield.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

More other tips for boiler

Source: Vitotronic 300 Installation and Service Instructions, p. 25. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.