Viessmann Boiler: Underfloor heating mixing circuit must be M1 with supply and return sensors

Updated · by Aurora Star Tech Inc.

Underfloor heating mixing circuit must be M1 with supply and return sensors on a Viessmann boiler: If the underfloor heating is controlled with supply and return temperature sensors (optimised control), the underfloor heating mixing valve circuit must be M1. Coding addresses C7 and C9 must also be checked for this optimised control.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitotronic 200-H system version 2 (underfloor heating)

How to fix underfloor heating mixing circuit must be m1 with supply and return sensors: step by step

  1. Connect the underfloor heating mixing valve circuit to M1.
  2. Check coding addresses C7 and C9 for optimised underfloor heating control.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

HK1BHK1MHK1SHK3SVitotrol 200Vitotrol 300

More commissioning tips for boiler

Source: Vitotronic 200-H installation and service instructions, p. 5. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.