Viessmann Boiler: Chimney and vent requirements
Chimney and vent requirements on a Viessmann boiler: Improper sizing, termination or blockage can send flue gases into the living space and cause carbon monoxide poisoning.
Applies to: VR1 22 to 33, 91 to 140
Common causes of chimney and vent requirements
- Blocked vent or chimney from birds' nests, ice, snow, debris or other material
- Improper sizing or termination
- Unlined chimney
- Excess depressurization from exhaust devices
- Chimney draft below the mildest weather draft
How to fix chimney and vent requirements: step by step
- Use only approved vent material and install the vent to all applicable local and national codes.
- Use a masonry, concrete or metal chimney built to code. Factory built chimneys must be listed and installed to the manufacturer's instructions.
- Make sure the chimney is clean-out equipped with a tight removable cap that stops air entering.
- Do not connect this boiler to an unlined chimney.
- Inspect the chimney for material, condition and size.
- Connect the oil appliance to its own chimney vent used for no other appliance, unless the codes allow otherwise.
- Do not connect the vent connector to any positive pressure mechanical draft system.
- Inspect the house for exhaust devices that could depressurize it, and tell the owner in writing if they could affect the boiler.
- Confirm chimney draft in cold weather testing and during mild weather.
- Keep sufficient fresh air supplied to the room for combustion.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitorond 100 installation and service manual, p. 14. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.