Viessmann Boiler: Wiring pumps that draw more than 2 FLA or are 3-phase/240V

Updated · by Aurora Star Tech Inc.

Wiring pumps that draw more than 2 FLA or are 3-phase/240V on a Viessmann boiler: Pumps above 2 FLA, 208/460/575V three-phase pumps and 240V pumps must be switched through a field-supplied contactor or relay rated 120VAC 1A, fed from a power supply with disconnect and protection on a DIN rail. Pumps under 2 FLA can be wired directly.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Pump wiring

How to fix wiring pumps that draw more than 2 fla or are 3-phase/240v: step by step

  1. Fit a contactor or relay rated 120VAC 1A on the DIN rail.
  2. Feed the contactor from a power supply with disconnect and protection.
  3. Wire the pump through the contactor.
  4. For pumps under 2 FLA, wire the pump directly to the DIN rail.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

Vitotronic 200

HO1BKW2Vitotronic 200, type H01BVitotronic 200, Type HO1B

Vitotronic 300-K

MW1SVitotronic 300-K, type MW2B

Source: Vitotronic 200 and 300-K Installation and Service, p. 18. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977