Viessmann Boiler: Install valve actuator adaptor and wire valve

Updated · by Aurora Star Tech Inc.

Install valve actuator adaptor and wire valve on a Viessmann boiler: Fit the 120 V or 24 V valve adaptor and connect the actuator.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Boiler return mixing or isolation/modulating valve actuator (VD2/VD2A/CT3)

How to fix install valve actuator adaptor and wire valve: step by step

  1. Disconnect power to the control.
  2. Mount the 120 V or 24 V valve adaptor on the DIN rail inside the connection enclosure.
  3. Insert plug gS into socket gS on the control.
  4. Secure the cable with a tie.
  5. Connect the adaptor black wire to terminal 8, 9 or 10 on connection aBH.
  6. Connect the valve actuator wires to the adaptor terminals as shown in the figures.
  7. Set the operating time via coding address 40 (5 to 199 s).
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

Vitotronic 100, type GC1

Source: Vitotronic 100 GC1 installation and service instructions, p. 56. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.