Viessmann Boiler: Hang the boiler on the wall bracket
Hang the boiler on the wall bracket on a Viessmann boiler: Remove the external accessories connection box cover, loosen the bottom screws without fully removing them, remove the front enclosure panel, hang the boiler on the bracket, and level it with the levelling screws. Level both vertically and horizontally so condensate drains properly. Fit the supplied installation fittings per the layout.
Applies to: Vitodens 200-W B2HA 80 to 100, 285 to 352
How to fix hang the boiler on the wall bracket: step by step
- Remove the external accessories connection box cover.
- Loosen the bottom screws without removing them.
- Lift the front enclosure panel up and pull it away from the boiler.
- Mount the boiler onto the bracket.
- Adjust the levelling screws until a round bubble level on top of the boiler reads level.
- Install the supplied installation fittings per the layout on page 11.
- Check that the boiler is level both ways so condensate drains.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitodens 200-W B2HA installation instructions, p. 15. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.