Viessmann Boiler: Change rotational direction of mixing valve motor

Updated · by Aurora Star Tech Inc.

Change rotational direction of mixing valve motor on a Viessmann boiler: Set the motor's rotation direction to suit the piping layout. The motor is delivered wired for the standard examples, so only change the wiring if the installation example needs it.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitotronic 200 KW2 mixing valve motor

How to fix change rotational direction of mixing valve motor: step by step

  1. Unscrew the motor cover.
  2. Turn the motor 180° and reconnect the connector.
  3. Check the wiring against the installation example (marker notch, HR heating return, HS heating supply, BR boiler return, BS boiler supply).
  4. Do not change the connections if the installation matches the delivered wiring.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

HO1BKW2Vitotronic 200, type H01BVitotronic 200, Type HO1B

Source: Vitotronic 200 service instructions, pp. 73-74. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.