Viessmann Boiler: System layout 6: two mixing-valve circuits with low-loss header
System layout 6: two mixing-valve circuits with low-loss header on a Viessmann boiler: One radiator circuit without a mixing valve and two underfloor circuits with 3-way mixing valves, with a low-loss header and DHW storage. Used when combined flow is above boiler maximum.
Applies to: Two underfloor circuits with mixing valves and DHW
How to fix system layout 6: two mixing-valve circuits with low-loss header: step by step
- Install the low-loss header and its Viessmann temperature sensor.
- Install a mixing valve accessory kit for each underfloor circuit.
- Pipe the DHW circulating pump into the boiler.
- Set the boiler pump and heating circuit pumps as shown in the layout.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
B2HB 45B2HB 45, 160B2HB 57B2HB 57, 199B2HB 160B2HB 199
Source: Vitodens 200-W B2HA installation manual, p. 38. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.