Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Boiler: Clean condensate trap

Updated · by Aurora Star Tech Inc.

Clean condensate trap on a Viessmann boiler: Clean the condensate trap during regular maintenance. Blocked drainage makes condensate build up in the boiler and causes a burner shut-down with a fault message.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 200-W B2HA

How to fix clean condensate trap: step by step

  1. Remove the rubber cap below the condensate trap.
  2. Unscrew the threaded cap. It may need to be pried off.
  3. Clean out debris from the trap.
  4. Refit the threaded cap and rubber cap.
  5. Undo the union nut and pull the trap down off the boiler.
  6. Fill the trap with water.
  7. Reassemble in reverse order.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

More other tips for boiler

Source: Vitodens 200-W B2HA 112, 150, 399, 530 Service Instructions, p. 27. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.