Viessmann Boiler: Connecting a mixing valve actuator

Updated · by Aurora Star Tech Inc.

Connecting a mixing valve actuator on a Viessmann boiler: A 120V or 24V valve adaptor on the DIN rail links the control to the mixing valve actuator. Power to the control must be off during the work.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitotronic 200-H HK1B, heating circuits 1 to 3 mixing valves

How to fix connecting a mixing valve actuator: step by step

  1. Disconnect power to the control.
  2. Install a 120V or 24V valve adaptor on the DIN rail inside the connection enclosure.
  3. Insert the gS plug into the gS socket on the Vitotronic control.
  4. Fasten the cable with a tie.
  5. Connect the black wire of the adaptor to terminal 8, 9 or 10 on the DIN rail.
  6. Connect the valve actuator wires to the adaptor terminals.
  7. Refer to the mixing valve adaptor installation instructions.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

HK1BHK1MHK1SHK3SVitotrol 200Vitotrol 300

Source: Vitotronic 200-H, HK1B Installation and Service Instructions, p. 19. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.