Viessmann Boiler: Carbon monoxide detector and signage requirements (Massachusetts)
Carbon monoxide detector and signage requirements (Massachusetts) on a Viessmann boiler: For side-wall horizontally vented installations in Massachusetts, a hard-wired CO detector with battery backup must be on the floor level where the gas equipment is installed, and detectors must be on each additional level. Signage is also required. Exemptions apply to certain equipment and to units in a separate structure.
Applies to: Side-wall horizontally vented installations in Massachusetts
How to fix carbon monoxide detector and signage requirements (massachusetts): step by step
- Confirm a hard-wired CO detector with alarm and battery backup is installed on the equipment's floor level.
- Confirm a battery or hard-wired CO detector is installed on each additional level.
- Confirm the required metal or plastic sign is mounted at least 8 ft above grade in line with the vent terminal.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
B2HB 45B2HB 45, 160B2HB 57B2HB 57, 199B2HB 160B2HB 199
Source: Vitodens 200-W B2HB 19 to 35, 68 to 125 service instructions, p. 8. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.