Viessmann Boiler: Connecting several remote controls
Connecting several remote controls on a Viessmann boiler: With more than one remote control, use the KM-BUS Expansion Module (accessory, Part No. 7133 393) or a field-supplied junction box. If only remote controls are on the bus, plug each one into the KM-BUS Expansion Module. If other KM-BUS participants are present, wire everything through a junction box. Total cable length must not exceed 50 m (164 ft).
Applies to: Multiple Vitotrol remote controls on one control unit
How to fix connecting several remote controls: step by step
- Use the KM-BUS Expansion Module (Part No. 7133 393) or a field-supplied junction box.
- If only remote controls are connected, plug each one into the KM-BUS Expansion Module.
- If other KM-BUS participants are connected, wire all devices through the junction box.
- Keep total cable length at or below 50 m (164 ft).
If the unit shows an error code, look it up: Viessmann Boiler codes
More commissioning tips for boiler
Source: Vitotrol 200 installation instructions, p. 3. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.