Viessmann Boiler: Vertical piping installation (boiler connections)
Vertical piping installation (boiler connections) on a Viessmann boiler: Connect the water and DHW pipes from the top of the boiler, then secure the bottom connections and gas line.
Applies to: Vitodens 222-F, B2TB vertical piping
How to fix vertical piping installation (boiler connections): step by step
- Fit the O-rings over the male boiler fittings and check they sit in the groove.
- Slide the insulation sleeve over the DHW pipe.
- Pass the pipes through the top cutouts of the boiler.
- Line up the pipes with the boiler fittings and push from the top until snug.
- Secure the pipe ends into the correct restraining rings.
- Fit the supplied locking clips over the bottom boiler connection and pipes.
- Remove the cap from the factory-installed gas line.
- Install the supplied tees, drain valves and gas valve as shown in the manual.
- Fit security clips to the DHW pipe retaining clips.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
222-F B2TB 19222-F B2TB 35222-F B2TB 68222-F B2TB 125B2TB 19B2TB 35B2TB 68B2TB 125VD2T 1HC1T4ZP.01VD2T 1HC1T4ZV.01Vitodens 222-F, B2TB 19Vitodens 222-F, B2TB 35Vitodens 222-F, B2TB 68Vitodens 222-F, B2TB 125
Source: Vitodens 222-F, B2TB installation instructions, p. 24-25. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.