Barometric draft regulator type and size on a Viessmann boiler: Choose the regulator type by fuel. The regulator opening must match the chimney it serves, not the boiler breeching.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitorond 200 VD2A oil and gas boilers

How to fix barometric draft regulator type and size: step by step

  1. On natural gas or propane, use a double-acting barometric draft regulator.
  2. On No. 2 fuel oil, use a single-acting barometric draft regulator.
  3. Size the regulator opening to the chimney diameter the vent is designed for.
  4. Do not size the regulator to the boiler breeching outlet unless the chimney is the same diameter.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

More other tips for boiler

Source: Vitorond 200 VD2A technical data manual, p. 24. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.