Updated · by Aurora Star Tech Inc.

Connecting several remote control units on a Viessmann boiler: Several remote controls and additional KM BUS users are connected through a junction box installed on site. Version 1 is for remote controls only; version 2 also adds other KM BUS users.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Multiple Vitotrol remote controls on KM BUS

How to fix connecting several remote control units: step by step

  1. Install a junction box on site.
  2. Connect the control unit, Vitotrol 1, 2 and 3 through the junction box as shown in the connection diagram.
  3. For version 2, connect additional BUS users through the same junction box.
  4. Keep the total length of all KM BUS cables to 50 m / 164 ft.
  5. Keep each remote control branch to a maximum of 15 m.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

HK1BHK1MHK1SHK3SVitotrol 200Vitotrol 300

Source: Vitotronic 200-H installation and service instructions, p. 47. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.