Viessmann Boiler: Operating program levels
Operating program levels on a Viessmann boiler: The operating program is set per heating circuit and has three levels: Heating and DHW, DHW only, and Standby mode. Special programs can be set externally or by a holiday program.
Applies to: Each heating circuit on Vitotronic 300-K
How to fix operating program levels: step by step
- Heating and DHW: rooms follow the room temperature and time program, and DHW follows its own program.
- DHW only: DHW follows its program, no central heating, frost protection for boiler and DHW tank is active.
- Standby mode: no central heating, no DHW heating, frost protection for boiler and DHW tank is active.
- External hook-up: changed by an external device such as an EA1 extension.
- External program: changed over by the Vitocom communication interface.
- Holiday program: the holiday program you created is active.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
MW1SVitotronic 300-K, type MW2B
Source: Vitotronic 300-K, MW2C Operating Instructions, p. 10. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.