Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Boiler: Connect a low water cut-off device

Updated · by Aurora Star Tech Inc.

Connect a low water cut-off device on a Viessmann boiler: Wire the LWCO switch contact into the safety circuit at plug aBÖ.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitotronic 300 GW6B

How to fix connect a low water cut-off device: step by step

  1. Remove the jumper between terminals 21(L) and 22(L).
  2. Connect the LWCO switching contact to terminals 21(L) and 22(L).
  3. Power the low water cut-off device from a free terminal 14, 15, 16 or 17 (L, N, G).
  4. Refer to the LWCO manufacturer manual for interconnection details.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Vitotronic 300, GW6B installation and service instructions, p. 36. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977