Viessmann Boiler: Remove the burner assembly
Remove the burner assembly on a Viessmann boiler: Remove the burner for inspection or cleaning. Do not lay the burner on its cylindrical tube or touch the tube mesh.
Applies to: Vitodens 222-F B2TB 19, 35, 68, 125
How to fix remove the burner assembly: step by step
- Switch off the main power and the ON/OFF switch 8.
- Close the gas shut-off valve and secure it against reopening.
- Remove the front upper panel (page 11).
- Flip down the control console (page 11).
- Remove the boiler inner cover.
- Unplug the cables from fan motor A, gas valve B, ionization electrode C, ignition unit D and ground wire E.
- Disconnect the gas supply pipe fitting F.
- Remove four Torx screws G.
- Remove the burner assembly.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
222-F B2TB 19222-F B2TB 35222-F B2TB 68222-F B2TB 125B2TB 19B2TB 35B2TB 68B2TB 125VD2T 1HC1T4ZP.01VD2T 1HC1T4ZV.01Vitodens 222-F, B2TB 19Vitodens 222-F, B2TB 35Vitodens 222-F, B2TB 68Vitodens 222-F, B2TB 125
Source: Vitodens 222-F B2TB service instructions, p. 22. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.