Viessmann Boiler: Install the control unit front (VD2/VD2A/CT3)
Install the control unit front (VD2/VD2A/CT3) on a Viessmann boiler: Reattaching the front housing of the Vitotronic 100 GC1 after wiring.
Applies to: Vitotronic 100 GC1 on VD2/VD2A/CT3 boilers
How to fix install the control unit front (vd2/vd2a/ct3): step by step
- Position the front housing and clip the hinges onto the main housing.
- Release the stay bar, open it up and lock it at point A.
- Insert the flat cable from the Optolink into plug X20.
- Insert the programming unit plug into plug X10 and route the cable through the cover guides.
- Engage the stay bar in the front housing.
- Close the front housing.
- Secure the front housing with the supplied screws.
- Install the connection enclosure cover and secure it with the supplied screw.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Source: Vitotronic 100 GC1 / Vitocontrol-S VD2/CT3/CM2 installation manual, p. 68. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.