Viessmann Boiler: Installing control and junction box (CM2)
Installing control and junction box (CM2) on a Viessmann boiler: Route cables and capillaries from the control to the junction box and mount the control on the panel.
Applies to: CM2 control and junction box
How to fix installing control and junction box (cm2): step by step
- Route cables and capillaries from the control through the opening in the control panel.
- Guide cables to the junction box through the rear panel opening and along the top rail to the control.
- Secure all cables to the rail with cable ties.
- Insert capillaries into the sensor well.
- Keep cables away from hot metal components.
- Mount the control to the control panel and secure it with screws (supplied with the cosmetic cover in the jacketing package).
- Mount the junction box to the rear panel on the right or left side with 4 x 4.8 metal screws.
- The ground screw and ground wire may be removed and reinstalled with the boiler back panel attached.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Source: Viessmann Vitotronic 100 GC1 installation and service instructions, p. 39. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.