Install boiler safety devices and pressure relief discharge piping on a Viessmann boiler: Fit the factory pressure relief valve and air vent, then run the discharge pipe to a floor drain. The discharge must never go outdoors.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitocrossal 300 CU3A 26 to 199

How to fix install boiler safety devices and pressure relief discharge piping: step by step

  1. Apply pipe sealant to both ends of fittings B, D, F and G, then fit them into coupling A and tees C.
  2. Install the pressure relief valve H and the air vent E and tighten both.
  3. Run the relief discharge pipe with an unthreaded end, and end it about 6 in. (150 mm) above the floor drain.
  4. Do not fit any shutoff valve in the discharge pipe, do not reduce its diameter (minimum 3/4 in.), and do not fit an isolation valve between the boiler and the relief valve.
  5. Position the discharge so it cannot scald anyone nearby.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

CU3I 2ZC2ZP.01CU3I 3HC/Z3ZP.01CU3X 1ZC1ZP.01Vitocrossal 300 CU3A 26Vitocrossal 300 CU3A 35Vitocrossal 300 CU3A 45Vitocrossal 300 CU3A 57Vitocrossal 300 CU3A 94Vitocrossal 300 CU3A 125Vitocrossal 300 CU3A 160Vitocrossal 300 CU3A 199

Source: Vitocrossal 300 CU3A 26 to 199 installation instructions, p. 16. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977