Viessmann Boiler: Remote heating on via telephone switch
Remote heating on via telephone switch on a Viessmann boiler: A remote contact can force heating on from the controller input.
Applies to: Versatronik COMO OT
How to fix remote heating on via telephone switch: step by step
- Wire the telephone switch to terminals 3 and 4.
- When the contact closes, the controller switches to heating at the set room temperature.
- When the contact opens, heating returns to the set operating mode or heating program.
- If full-time reduced operation is wanted (for example a weekend home), program the controller so that a closed contact uses the normal room temperature settings.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Versatronik COMO OT installation and operating manual, p. 33. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.