Viessmann Boiler: Pressure relief valve discharge piping

Updated · by Aurora Star Tech Inc.

Pressure relief valve discharge piping on a Viessmann boiler: No valve may be installed between the pressure relief valve and the boiler. Discharge piping must be sized and routed per the ASME code and drained safely.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Boiler pressure relief valve piping

How to fix pressure relief valve discharge piping: step by step

  1. Do not install any valve between the relief valve and the boiler.
  2. Make the discharge pipe full size of the valve outlet, as short and straight as possible.
  3. Place any elbow close to the valve outlet.
  4. Route discharge so no one can be scalded and so the pipe can be drained.
  5. Keep the pipe size and layout so pressure cannot reduce relieving capacity.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Vitorond 200 VD2 installation manual, p. 26. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.