Viessmann Boiler: Set the domestic hot water (DHW) time program
Set the domestic hot water (DHW) time program on a Viessmann boiler: Set DHW heating times, or use automatic mode, which follows the space heating program but starts 30 minutes earlier. The DHW re-circulation pump runs with the DHW program.
Applies to: Vitotronic 200-H DHW heating and DHW re-circulation pump
How to fix set the domestic hot water (dhw) time program: step by step
- Open the hinged cover on the programming unit.
- Press uw; the 'DHW time program' display appears.
- Press the up/down buttons for 'Automatic?' or 'Individual?' and confirm.
- For individual times, choose '1-7' for all days or a single weekday (Mo, Tu, etc.) and confirm.
- Set the ON and OFF times for DHW phase 1, confirming each one. Phases 2 to 4 are set the same way.
- To skip a phase, use the skip button.
- Close the hinged cover.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
HK1BHK1MHK1SHK3SVitotrol 200Vitotrol 300
Source: Vitotronic 200-H operating instructions, p. 17-18. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.