Viessmann Boiler: Piping layout: multiple heating circuits with mixing valves and low-loss header
Piping layout: multiple heating circuits with mixing valves and low-loss header on a Viessmann boiler: Boiler with DHW storage tank, low-loss header, several mixing-valve heating circuits and one circuit without a mixing valve. Viessmann recommends contacting the local sales representative for design help.
Applies to: Vitodens 200-W B2HB with Vitotronic 200 control
How to fix piping layout: multiple heating circuits with mixing valves and low-loss header: step by step
- Pipe all circuit pumps and the DHW circulating pump so they pump into the boiler, as shown in the drawing.
- Locate the expansion tank as the drawing shows.
- Install the Viessmann temperature sensor for the low-loss header.
- Use the accessory mixing-valve kit or a Vitotronic 200-H HK1B mixing-valve control with LON module for each mixed circuit.
- Set the function of the programmable pump output by coding address 53.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Vitodens 200-W B2HB 45Vitodens 200-W B2HB 57Vitodens 200-W B2HB 160Vitodens 200-W B2HB 199
Source: Viessmann Vitodens 200-W B2HB technical data manual, p. 41. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.